廣州澤爾機(jī)電科技有限公司
主營(yíng)產(chǎn)品: 德國(guó)ziehl繼電器、溫控器 |
會(huì)員1.png)
![]() |
廣州澤爾機(jī)電科技有限公司
主營(yíng)產(chǎn)品: 德國(guó)ziehl繼電器、溫控器 |
2016-8-26 閱讀(443)
廣州澤爾機(jī)電科技有限公司是德國(guó)ziehl在中國(guó)的*辦事處,負(fù)責(zé)正規(guī)渠道的銷售和服務(wù),產(chǎn)品劉。
Pt 100 temperature relay for up to 12 sensors with electric 10 MBit/s Ethernet interface
Pt100溫度繼電器可接多達(dá)12個(gè)傳感器,并帶有10MB/s的電子網(wǎng)絡(luò)接口
Order-number廠家訂貨號(hào)
T224078
AC/DC 24-240 V
Approvals認(rèn)證有:
The TR1200IP can be used wherever multiple Pt 100 sensors (up to 12) need to be evaluated simultaneously:
TR1200IP能用在任何并聯(lián)的Pt100傳感器(多達(dá)12個(gè))需要同時(shí)評(píng)估的地方。
· Motors or generators,馬達(dá)或者電機(jī)
· also with simultaneous monitoring of bearings or, e.g., exhaust temperatures同樣可用于同時(shí)監(jiān)測(cè)軸承溫度或者排氣溫度。
· Transformers, also with additional core-temperature monitoring變壓器,還能監(jiān)測(cè)其內(nèi)核溫度。
· Machines and plants機(jī)器和工廠。
Type TR1200IP temperature relays register the temperature of up to 12 sensors simultaneously and provide the values to the electric 10 MBit/s Ethernet interface. 2 IP protocols are supported, so the registered temperatures can be subsequently evaluated by connected devices that are linked with the TR1200IP via an Ethernet network.
TR1200IP溫度繼電器可同時(shí)記錄多達(dá)12個(gè)傳感器的溫度,并把這些數(shù)值傳供給10MB/s的電子網(wǎng)絡(luò)接口,支持2路IP協(xié)議,因此這些記錄的溫度隨后能夠被連接的設(shè)備進(jìn)行評(píng)估,這些設(shè)備通過因特網(wǎng)與TR1200IP連接。
In motors, that could be a motor contactor, in transformers a transformer contactor with integrated overload function and thermal monitoring. An alarm relay reports devices and sensor errors. Sensor breaks or sensor short-circuits are also transmitted via the protocol to the connected evaluation unit.
在電機(jī)里,TR12000IP可為一個(gè)電機(jī)接觸器;在變壓器里,可為一個(gè)帶綜合超載功能和熱量監(jiān)測(cè)的變壓器接觸器。一個(gè)報(bào)警繼電器可報(bào)告裝置和傳感器的錯(cuò)誤。傳感器失靈或傳感器短路同樣會(huì)通過通訊協(xié)定傳遞給連接的評(píng)估單元。
· 3-digit digital display for the temperature of up to max. 12 measuring points
· 3位數(shù)數(shù)字顯示,顯示zui多至12個(gè)測(cè)量點(diǎn)的溫度。
· 12 sensor inputs; 1…12 sensors can be connected
· 12路傳感器輸入,1-12傳感器可連接。
· Pt 100 in 2- or 3-wire technology, when connecting Ni100 or Ni120, conversion to the correct temperature in the evaluation unit is required, SIPROTEC devices from Siemens (e.g. 7SK80) support this function. The EN100 module in the SIPROTEC 4 units does not support the TR1200 IP.
· 1 alarm relay (1 change-over contact)
· Electric 10 MBit/s Ethernet interface (RTD IP protocol from ZIEHL, or Modbus IP protocol)
· Read-out display, configuration, simulation and firmware update via Web browser
· Tested with Mozilla Firefox 3.5 and Microsoft Internet Explorer 8.0
· LEDs for measurement allocation, error, relay status and Ethernet interface
· Code protection against manipulation of the setpoint values
· Wide area power supply AC/DC 24…240 V
· Distributor housing for panel mounting 8 TE, front-to-back size 55 mm
· Mounting on 35mm DIN EN 60715 standard rail
Rated Supply Voltage Us
.......
AC/DC 24-240 V, 0/45...65 Hz, < 5 VA
DC: 20,4...297 V, AC: 20,4...264 V
Relay output
.......
1 change-over contact (CO)
Type 2, see general technical information
Measuring inputs
.......
12 x Pt100 (RTD) according to EN 60 751 / IEC 60 751
Measuring time sensor
.......
0,25...3s (depending on number of sensors)
Measuring range
.......
-199°...850°C
Resolution
.......
1°C
Tolerance
.......
± 0,5% of value ± 1 K
Sensor-current
.......
≤ 0,8 mA
Ethernet interface
IP-adress
.......
selectable
Subnet mask
.......
selectable
UDP Port
.......
selectable 0...65535
Max. cable-length
.......
max. 20 m with CAT 5 patch-cable
Max. response time
.......
200 ms
Testing conditions
.......
see general technical information
Rated ambient temperature range
.......
-20°C...+65°C
Housing
.......
Design V8
Dimensions (w x h x d)
.......
140 x 90 x 58 mm, mounting height 55 mm
Protection housing/terminals
.......
IP 30 / IP 20
Attachment
.......
DIN-rail 35 mm acc. to EN 60715 or screws M4
Gewicht
.......
ca. 350 g