PR5230變送器
概述
The Transmitter PR5230 provides an easy and reliable solution for weighing of process hopper scales with strain gauge load cells in process automation applications.
The standard RJ45 connector provides ModBus TCP and also Ethernet TCP|IP for an easy integration into existing PLC and PC networks. Information can be transferred into supervisory systems with the OPCServer technology. Sartorius PR5230
The PR 5230 Transmitter provide a built-in RS232 and RS422/485 serial interface using the very simple and versatile SMA-Standard protocol and the protocol for a remote display. A printer can be connected to printout the configuration but also print a ticket with an incoming event (input) or e.g. every 30 minutes at regular time schedule.
特性
- Ethernet TCP|IP for PC connection to OPC Server or configuration by Browser
- Modbus TCP for PC and PLC connections
- Webservice via SOAP|UPnP
- Serial Interface RS485/422 and RS232
- 3 digital in- and 3 outputs (Relays)
- W&M approval for 10.000 e, class III (In preparation)
- Calibration without weights (Smart Calibration)
- Strain gauge and Sartorius digital scales can be connected
- Display for Weight and Status Information
- ATEX Ex approval for use in Zone 2/22
- Intrinsically safe load cell connection for load cells in Zone 1/21
參數(shù)
Housing Housing IP66 material: stainless steel electro polished RoHS conform Dimensions 350 + 250 + 150 mm Weight Net: 1.45 kg Display and Status LCD, transflective, back lighted Weight: 6-digits Size: 128 + 64 pixel, graphic Information can be configured Status LEDs to signal operation and error conditions. Internal Keys In the housing 3 keys for Zero, Tare, Test Supply Voltage 230 VAC, +10/-15 % 24 VDC, +/-20 % Power Consumption 11 W Control Outputs Quantity: 3 Relay output, passive, Functions: Limits, weight status... Voltage: max. 30 VDC Current: max. 30 mA Control Inputs Quantity: 3 opto-isolated input, passive, Functions: zero setting, taring... Voltage: max. 30 VDC Current: max. 10 mA Remote I|O The I|O can be set internally via a function and remote via fieldbus or PC All I | O circuits fully galvanically isolated from sensor input and supply. Load cell connection All strain gauge load cells; 6- or 4-wire connection Load Cell Supply 12 V, short-circuit proof. External load cell supply possible. Minimum Load Impedance min. 75 O e.g. 6 load cells with 600 O or 4 load cells with 350 O Measuring Principle Measuring amplifier: Delta-Sigma converter Measuring time: min 5 ms – max. 1600 ms Accuracy 7.5 nV (appr. 4.8 Mio. div.) Usable resolution: 0.2 μV/d | LC Input Signal Measuring signal: 0 bis 36 mV (for 100 % nominal load) W&M Approval (in preparation) 10,000 e class III acc. to EN 45501; according to. OIML R 76, min. verification interval: 0.5 μV/e at 160 ms Linearity < 0.003 % Temperature effects Zero: TK0 m < 0.05 μV/K RTI Span: TKspan < +/- 2.5 ppm/K Digital filter for load cell 4th order (low pass), Bessel, aperiodic or Butterworth Ethernet interface (functions) – Ethernet TCP|IP and Modbus TCP – Definition of an IP adress: – AutoIP – DHCP Server classification – manual entering of an IP adress – Automatic detection of signal transmission and corresponding change over (cross-over or patch cable) – Webservice via SOAP|UPnP (Simple Object Access Protocol) – Synchronal Modbus UDP Serial Interfaces RS 422/485 and RS232 Protocols: Remote Display, SMA, Modbus RTU, printer and Sartorius digital scales (XBPI – protocol) Options: Analogue output PR 5230/06 (C11) 0/4 … 20 mA, internal resolution 16 bit, usable stepwidth: 0.5 μA max. load 500 O, user configurable Fieldbus PR 1721/4x (C2x) Profibus-DP, Interbus-S, DeviceNet, CC-Link, Profinet and Ethernet | IP Load Cell connection Board PR 5230/22 (C31) For the internal connection of up to 4 Load cells. (instead using a cable junction box) Environmental conditions Temperature W&M: –10 °C to +40 °C Operation: –10 °C to +50 °C Storage: –20 °C to +70 °C ATEX Approvals PR 5230: II 3G Ex nA nC IIC T4 II 3D Ex tD A22 IP6X T80°C SAG 09ATEX004X II (2)G [Ex ib] IIC II (2)D [Ex ibD] KEMA 10 ATEX 0065 X |
訂貨型號(hào)
PR 5230 Transmitter in field housing, IP66, stainless steel, 9405 152 30000
incl. Ethernet TCP| IP and Modbus TCP, RS232,
RS485/422, 3 Relays Outputs, 3 Digital Opto.
Inputs OPC Server License included
配件
- Analogue output 0/4 –20 mA,
- Profibus-DP, Interbus-S, DeviceNet, CC-Link, Profinet and Ethernet |IP,
- Load Cells connection board for up to 4 Load Cells
- PR 5230/06 Analog Output 0/4-20 mA 9405 352 30061
- PR 5230/22 Load Cell connection board for up to 4 Load Cells 9405 352 30221
- (instead using a cable junction box)
- PR 5230/30 Ethernet female connector RJ45, IP66 9405 352 30301
- PR 5230/31 Ethernet cable with cable glance, 7M, RJ45 plug 9405 352 30311
- PR 1721/41 Profibus-DP 9405 317 21411
- PR 1721/42 Interbus-S 9405 317 21421
- PR 1721/44 DeviceNet 9405 317 21441
- PR 1721/45 CC-Link 9405 317 21451
- PR 1721/46 Profinet 9405 317 21461
- PR 1721/47 Ethernet |IP 9405 317 21471